The Mantis™ LW-MM200 is the first live cable testing and reporting module that monitors energized cable runs and electrical circuits around-the-clock. It detects, locates, and characterizes faults, either static/persistent or intermittent, and reports where and when they occur. This information can then be transmitted wirelessly or over data cables for alerts and instant response to the event or outage.
The Mantis uses revolutionary Spread Spectrum Time Domain Reflectometry (SSTDR) technology to “see” into the cable environment and watch for changes that could lead to outages or alert system owners of tampering and removal of electrical cables.
Saves reports transferrable to PCs for storage and printing
Cable fault finding or end point discovery and associated locations
Enterprise application software and map- and device-based dashboards available for monitoring and control of multiple Mantis units.
DIN rail mounting
Waterproof enclosure optional
Remote software update / upgrade availability
MANTIS ENTERPRISE APPLICATION (MEA)
Mantis Enterprise Application (MEA) is a multi-tiered application which permits a large number of Mantis devices to interact with a single system. The MEA can be monitored and controlled from anywhere there is an internet connection. All data sent by any Mantis device is stored in a database and that data can be viewed using any of the two dashboard-based User Interface (UI), a map-based dashboard and a device-based dashboard.
The Map-based Dashboard is intended for display in a control center and display each Mantis device at its location and shows the testing status of the Mantis device, like test is running and what test type is running. If a Mantis device detects a fault, the Map-based Dashboard will displays the fault information.
The Device-based Dashboard is intended for those who need to know more about the device other than a test is running or not and a fault is detected. The Device-based Dashboard displays key device health information, like battery status and device events.
Using the Device Control UI, users can control any of the Mantis device to include starting and stopping any of the three test types. The Device Control UI provides users with greater control of the Mantis device, like using advanced dynamic test settings. The Device Control UI allows users to view more information about faults, like graph views, and the Mantis devices themselves.
Size: 7.24”W x 6.83”H x 4.23”D
Weight: 2.25 lbs. (1.02 kg)
Power Supply
Input Voltage Range 10 to 28 VDC (12 V Nominal), 20W (110-240 VAC adapter available as optional accessory)During power failure, battery will keep Mantis functioning.
Battery
3100mAh totes Li-ion rechargeable
8-10 Hours Typical Battery Life for Back-up Power
4 hour typical charge time
Voltage Rating
The Mantis is designed for use on cabling systems with voltage up to 1000 Volts. Forhigher voltages, contact LiveWire. The Mantis unit is designed to ratings of CAT II 1000V/CAT III 600 V (6 kV transient).
Electrical connector interface
Easy-to-use terminal block for electrical connections
(Capacity 28 - 12 AWG gauge wire; with 0.20 inch x 0.33 inch maximum diameter insulation)
Measurement Method
Spread Spectrum Time Domain Reflectometry (SSTDR)
VOP Range
3-digit precision ranging from 20.0% to 99.9%
Distance to Fault Accuracy
+/- 2% accuracy for cables > 100 feet (+/- 1% for controlled impedance cables)
+/- 2 feet for cables < 100 feet
Note: Accuracy Range applies with known VOP and consistent cable parameters
Maximum Testable Distance/Length
Up to 20,000 ft. (6 km.) maximum testable cable length
Note: Maximum testable cable length varies with VOP and cable type. Contact LiveWire Innovation for cables beyond this length
Output Signal Amplitude
0.016 - 1.1 V peak-to-peak, adjustable to desired minimum/maximum amplitudes
Operating Environment
Operating temperature: -20 to 70 °C ( -4 to 158 °F)
Storage temperature: -30 to 85 °C (-22 to 185 °F)
Humidity: 10% to 90%, non-condensing
Altitude: 6,500 ft. (2,000m) operating
Communication Protocols
SSH over WiFi (modem not included) or wired ethernet (RJ45 jack included) or cellular coverage (Cellular USB dongle (not included) and service required)
Data Storage Limit
8 GB with automatic overwrite of oldest data if exceeded
Enterprise Software/Dashboards
Software and map- and device-based dashboards for monitoring and control of multiple Mantis units through PC interface.
PC or Tablet Interfaces
Easy-to-use Android tablet (not included) or Windows PC (not included) interfaces for controlling and reading info from the Mantis
No calibration needed
No metrology calibration required
English or metric measurements
International applications
Designed to Meet
(Pending)
ANSI/ISA 82.02.01 (61010-1) 2004
CAN/CSA-C22.2 No 61010-1-04
UL 61010-1
IEC/EN 1010-3 2nd Edition for measurement Category II, 1000 V
EMC EN61326-1
WEEE Compliant
Required Additional Equipment
Either an Android tablet (OS 4.0+; 1+GB RAM; 7”+ display with minimum resolution of 1280 x 800) or Windows PC (Windows 7+; 4+ GB memory) is required to set up or reprogram the Mantis, to start and stop certain static tests, and to read test results/data from the Mantis.
“[LiveWire Innovation] delivered and demonstrated a unit which we immediately used to accurately locate a cable fault on one of our sub-sea 5 KV cables. Prior to this we had used conventional TDR meters which had given us unreliable results and showed ghost signals which could have indicated additional faults that didn’t exist. The cost implications of this are huge.”
-Mike Mason, Dubai Petroleum
“[LiveWire Innovation] delivered and demonstrated a unit which we immediately used to accurately locate a cable fault on one of our sub-sea 5 KV cables. Prior to this we had used conventional TDR meters which had given us unreliable results and showed ghost signals which could have indicated additional faults that didn’t exist. The cost implications of this are huge.”
Fully housed sensor modules for permanent installation. Handheld products using LiveWire’s Spread Spectrum brand of TDR for maintenance, field testing and electrical contractor markets.
The Mantis™ LW-MM200 is the first live cable tester module that monitors energized cable run faults and electrical circuits around-the-clock.
Fault Trapper monitors live circuits for intermittent conditions to record time and distance to Opens, Shorts and Arc Faults.
Dual mode TDR for testing and monitoring energized and unenergized systems.
Mantis™
Live cable fault monitoring module
The Mantis™ LW-MM200 is the first live cable testing and reporting module that monitors energized cable runs and electrical circuits around-the-clock. It detects, locates, and characterizes faults, either static/persistent or intermittent, and reports where and when they occur. This information can then be transmitted wirelessly or over data cables for alerts and instant response to the event or outage.
The Mantis uses revolutionary Spread Spectrum Time Domain Reflectometry (SSTDR) technology to “see” into the cable environment and watch for changes that could lead to outages or alert system owners of tampering and removal of electrical cables.
Overview
PRODUCT FEATURES
MANTIS ENTERPRISE APPLICATION (MEA)
Mantis Enterprise Application (MEA) is a multi-tiered application which permits a large number of Mantis devices to interact with a single system. The MEA can be monitored and controlled from anywhere there is an internet connection. All data sent by any Mantis device is stored in a database and that data can be viewed using any of the two dashboard-based User Interface (UI), a map-based dashboard and a device-based dashboard.
The Map-based Dashboard is intended for display in a control center and display each Mantis device at its location and shows the testing status of the Mantis device, like test is running and what test type is running. If a Mantis device detects a fault, the Map-based Dashboard will displays the fault information.
The Device-based Dashboard is intended for those who need to know more about the device other than a test is running or not and a fault is detected. The Device-based Dashboard displays key device health information, like battery status and device events.
Using the Device Control UI, users can control any of the Mantis device to include starting and stopping any of the three test types. The Device Control UI provides users with greater control of the Mantis device, like using advanced dynamic test settings. The Device Control UI allows users to view more information about faults, like graph views, and the Mantis devices themselves.
Specifications
Weight: 2.25 lbs. (1.02 kg)
8-10 Hours Typical Battery Life for Back-up Power
4 hour typical charge time
(Capacity 28 - 12 AWG gauge wire; with 0.20 inch x 0.33 inch maximum diameter insulation)
+/- 2 feet for cables < 100 feet
Note: Accuracy Range applies with known VOP and consistent cable parameters
Note: Maximum testable cable length varies with VOP and cable type. Contact LiveWire Innovation for cables beyond this length
Storage temperature: -30 to 85 °C (-22 to 185 °F)
Humidity: 10% to 90%, non-condensing
Altitude: 6,500 ft. (2,000m) operating
CAN/CSA-C22.2 No 61010-1-04
UL 61010-1
IEC/EN 1010-3 2nd Edition for measurement Category II, 1000 V
EMC EN61326-1
WEEE Compliant
Support / Manuals
Reviews
“[LiveWire Innovation] delivered and demonstrated a unit which we immediately used to accurately locate a cable fault on one of our sub-sea 5 KV cables. Prior to this we had used conventional TDR meters which had given us unreliable results and showed ghost signals which could have indicated additional faults that didn’t exist. The cost implications of this are huge.”
-Mike Mason, Dubai Petroleum
“[LiveWire Innovation] delivered and demonstrated a unit which we immediately used to accurately locate a cable fault on one of our sub-sea 5 KV cables. Prior to this we had used conventional TDR meters which had given us unreliable results and showed ghost signals which could have indicated additional faults that didn’t exist. The cost implications of this are huge.”
-Mike Mason, Dubai Petroleum
Ordering Information
LW-MM200
Handheld Solutions
Fully housed sensor modules for permanent installation. Handheld products using LiveWire’s Spread Spectrum brand of TDR for maintenance, field testing and electrical contractor markets.
The Mantis™ LW-MM200 is the first live cable tester module that monitors energized cable run faults and electrical circuits around-the-clock.
Fault Trapper monitors live circuits for intermittent conditions to record time and distance to Opens, Shorts and Arc Faults.
Dual mode TDR for testing and monitoring energized and unenergized systems.
3-In-1 DMM/TDR Cable Fault Finder
Fault Finding/Cable Length Measurement TDR